Automatic monitoring, management, storage, and transmission of data from analog transducers for structural, geotechnical, and environmental monitoring.** This includes devices such
as crack meters, inclinometers, temperature probes, load cells, hydrometers, etc. It is a wireless data acquisition system that, together with mGateway, provides a versatile and autonomous Early Warning system ideal for short, medium, and long-term monitoring.
– Versatile
(structural, geotechnical, and environmental monitoring).
– Easy to install and use.
– Internal battery (3.6V) and external (12V) power supply. – Multi-connectivity: Digimesh® / LORAWAN®.
– Multi-channel: up to 3 analog transducers
(point and/or distributed monitoring).
– Integrated diagnostics (network, power, temperature, memory). – Automatic data transmission to mGateway.
– Long autonomy: 2 years
(typical, with one sensor and measurements every 60 minutes).
- HARDWARE CHARACTERISTICS:
- 1. Internal power supply: 3.6 VDC.
External power supply: 12 VDC.
Power consumption: Typical 45 mA
(max. 75 mA, min. 350 μA in sleep mode).
4. Operating temperature: Min. -20 °C, max. +60 °C.
Operating relative humidity: Min. 0%, max. 80%.
Memory: Internal memory for 48,512 readings
(e.g., with 3 sensors sampling hourly, 673 days of storage).
7. Case: IP65, dimensions: 160 x 90 x 50 mm (L x W x H).
- ANALOG CHANNELS:
- 1. ADC resolution: 24 bit.
Number of channels: 3
(differential or single-ended, software configurable).
Electrical range: 0 ÷ 5 V (single-ended), max. ± 2.5 V
(differential).
4. Sensor types: Inclinometers, potentiometers, resistive
bridges, PT100, thermistors, and thermocouples.
5. Sensor power supply: 2.5 V reference (max. 10 mA), 3.3
V (max. 250 mA), excitation current max. 1 mA, switching 12 VDC max. 100 mA.
- COMMUNICATION PORTS
- 1. UART for DIGIMESH® / LORAWAN® module; 2. USB for local configuration via PC;
- MAIN FUNCTIONALITIES AVAILABLE VIA THE INTEGRATED WEB SERVER ON THE MGATEWAY MODULE:
- 1. Transmission of acquired sensor data and diagnostics to mGateway.
Independent alarm event transmission to the concentrator.
Internal memory logging of acquisitions and alarms.
4. Configuration of connected analog transducers.
Monitoring battery charge status.
Monitoring internal/external power supply.
– User’s manual; – Omni-directional high-gain outdoor antenna; – USB cable for communication with PC; – 3.6 V lithium-ion battery (6.5 Ah);
Optional products: – 220 Vac mains power supply; – 220 Vac mains power supply box; – Solar panel power supply box + solar panel kit;
– Structural monitoring; – Geotechnical monitoring; – Environmental monitoring;
– Sheet updated on: 2023.11; – Specifications and standards subject to change without notice; – Check the website for the latest updates of the sheets, projects, and other product photos.